Conventions that apply to every endpoint (request format, the async and outputType parameters, and the response envelope) are in Requests and responses. In the tables below, Required is Yes when the parameter must always be supplied, No when it is optional, and Depends when it is required only in some combinations (for example, either an application and volume, or a consistency group ID); the CLI chapter for the same command explains the combinations.

PUT /resources/network/iscsi/add

Enable iSCSI traffic on specific IPs.

CLI command: resources network iscsi add

Body fields (JSON)

Name Type Required Description
Ips array of string Yes The IPs to enable iSCSI traffic on.

GET /resources/network/iscsi/list

List iSCSI IPs.

CLI command: resources network iscsi list

This endpoint takes no parameters.

Response: a list of NodeToIpElements objects in Result.NodeToIpElements, each with: NodeName (string), Ips (array of IPElement).

PUT /resources/network/iscsi/remove

Disable iSCSI traffic on specific IPs.

CLI command: resources network iscsi remove

Body fields (JSON)

Name Type Required Description
Ips array of string Yes The IPs to disable iSCSI traffic on.
Force boolean No Skip the confirmation prompt.

GET /resources/network/list

List all available network interface cards.

CLI command: resources network list

Query parameters

Name Type Required Description
errors boolean No Show only components with errors.
details boolean No Show advanced information.
ids array of integer No Filter by resource ID.

Response: a list of NodeElement objects in Result.

PUT /resources/network/nvmeof/edit

Enable or disable NVMeOF traffic on an IP.

CLI command: resources network nvmeof edit

Query parameters

Name Type Required Description
ip string Yes The IP address to enable/disable NVMeOF traffic on.

Body fields (JSON)

Name Type Required Description
Port integer Yes The port to enable/disable NVMeOF traffic on.
Enable boolean Depends Enable NVMeOF traffic. In REST one field covers a pair of CLI flags: true applies --enable, false applies --disable, and omitting the field applies neither.
Rdma boolean Depends Use RDMA as the transport for NVMeOF traffic.
Tcp boolean Depends Use TCP as the transport for NVMeOF traffic.

GET /resources/network/nvmeof/list

List NVMeOF IPs.

CLI command: resources network nvmeof list

This endpoint takes no parameters.

Response: a list of NodeToIpElements objects in Result.NodeToIpElements, each with: NodeName (string), Ips (array of IPElement).

GET /resources/network/ping

Run a ping test.

CLI command: resources network ping

Query parameters

Name Type Required Description
ip string Yes The IP address to ping.

Response: a list of NodeElement objects in Result.Nodes.


See also: Requests and responses - Authentication - Examples